Evaluation of the Entrance Surface Dose (ESD) and Radiation Dose to the Radiosensitive Organs in Pediatric Pelvic Radiography
Volume 5, Issue 6 , June 2017, , Pages 5013-5022
Abstract
Background Patients' dosimetry is crucial in order to enhance radiation protection optimization and to deliver low radiation dose to the patients in a radiological procedure. The aim ... Read MoreRadioprotection to the Gonads in Pediatric Pelvic Radiography: Effectiveness of Developed Bismuth Shield
Volume 5, Issue 6 , June 2017, , Pages 5153-5166
Abstract
Background: The use and effectiveness of traditional lead gonad shields in pediatric pelvic radiography has been challenged by several literatures over the past two decades. The aim ... Read MoreOptimization of Radiological Protection in Pediatric Patients Undergoing Common Conventional Radiological Procedures: Effectiveness of Increasing the Film to Focus Distance (FFD)
Volume 5, Issue 4 , April 2017, , Pages 4771-4782
Abstract
Background Increasing the x-ray film to focus distance (FFD), has been recommended as a practical dose optimization tool for patients undergoing conventional radiological procedures. ... Read MoreEvaluation of the Prevalence and Utility of Gonad Shielding in Pediatrics Undergoing Pelvic X-Ray
Volume 4, Issue 11 , November 2016, , Pages 3735-3740
Abstract
Background: Gonad shielding has been recommended during pelvic x-rays since the 1950s. The popular method of gonad shielding is placement a lead shield in the midline of the pelvis. ... Read MoreEfficacy of Increasing Focus to Film Distance (FFD) for Patient’s Dose and Image Quality in Pediatric Chest Radiography
Volume 4, Issue 9 , September 2016, , Pages 3421-3429
Abstract
Background: Increasing the x-ray focus to film distance (FFD) has been advocated as an effective method to reduce the patients’ radiation dose. The aim of this study was to investigate ... Read MoreDose Reduction to the Thyroid Gland in Pediatric Chest Radiography
Volume 4, Issue 7 , July 2016, , Pages 2183-2191
Abstract
Background It is remain a main concern that pediatric chest radiographies contribute to the significant radiation exposure to the thyroid gland as a more susceptible organ to ... Read MoreSurvey of the Use of X-ray Beam Collimator and Shielding Tools during Infant Chest Radiography
Volume 4, Issue 4 , April 2016, , Pages 1637-1642